Severity: Warning
Message: fopen(/opt/alt/php74/var/lib/php/session/ci_sessionf743c4b144595e8371a84d29f8bc941a40b8f6b5): failed to open stream: Disk quota exceeded
Filename: drivers/Session_files_driver.php
Line Number: 176
Backtrace:
File: /home/zytroni1/public_html/acmed.com/application/controllers/Website.php
Line: 8
Function: __construct
File: /home/zytroni1/public_html/acmed.com/index.php
Line: 318
Function: require_once
Severity: Warning
Message: session_start(): Failed to read session data: user (path: /opt/alt/php74/var/lib/php/session)
Filename: Session/Session.php
Line Number: 143
Backtrace:
File: /home/zytroni1/public_html/acmed.com/application/controllers/Website.php
Line: 8
Function: __construct
File: /home/zytroni1/public_html/acmed.com/index.php
Line: 318
Function: require_once
Severity: Warning
Message: imagejpeg(./captcha/1777567169.jpg): failed to open stream: Disk quota exceeded
Filename: helpers/captcha_helper.php
Line Number: 609
Backtrace:
File: /home/zytroni1/public_html/acmed.com/application/helpers/common_helper.php
Line: 354
Function: create_captcha
File: /home/zytroni1/public_html/acmed.com/application/controllers/Website.php
Line: 413
Function: generate_captcha
File: /home/zytroni1/public_html/acmed.com/application/controllers/Website.php
Line: 84
Function: singlecatalog
File: /home/zytroni1/public_html/acmed.com/index.php
Line: 318
Function: require_once
Download Catalog
Description:
Dialyzer Reprocessing Machine KDR-200 is an advanced dialyzer reprocessing unit equipped with touch screen interface to navigate, monitor and select various functional parameters and settings. Specialized inflow pressure sensor and blood volume sensor enables synchronous workflow. Comprehensive storage of time-stamped dialyzer data improves standardization and stores essential determinants for further use of dialyzer.
Specifications :
| Cycle time | 8 minutes per cycle |
|---|---|
| Volume test range | 0 mL to 150 mL ( ±3 % ) |
| Maximum water inlet flow | > 1600 mL/min |
| Water consumption | 8 L |
| Water input temperature | 10 °C to 30 °C |
| Water input pressure | 0.15 MPa to 0.35 Mpa |
| Pressure lost test | Low-flux dialyzer <0.83 mmHg/s High-flux dialyzer <1.25 mmHg/s |
| Standard rinse | 11 min for one or 22 min for two |
| Intensive rinse | 14 min for one or 27 min for two |
| Power supply | 220 V / 50 Hz |
| Dimensions | 480 × 430 × 560 mm |
| Weight | 25 Kgs |
Features :
Applications
Used in nephrology (AKD) departments in hospitals or Kidney dialysis centers to effectively automate reprocessing activities detect blood volume as well as inspect for dialyzer compliance with hospital infection-control measures for reuse of the dialyzer unit and provide recorded patient data for record keeping and quality control.