Severity: Warning
Message: fopen(/opt/alt/php74/var/lib/php/session/ci_session6a5e5f5dddd06b5a97849fdbe9bda64d59557bb0): failed to open stream: Disk quota exceeded
Filename: drivers/Session_files_driver.php
Line Number: 176
Backtrace:
File: /home/zytroni1/public_html/acmed.com/application/controllers/Website.php
Line: 8
Function: __construct
File: /home/zytroni1/public_html/acmed.com/index.php
Line: 318
Function: require_once
Severity: Warning
Message: session_start(): Failed to read session data: user (path: /opt/alt/php74/var/lib/php/session)
Filename: Session/Session.php
Line Number: 143
Backtrace:
File: /home/zytroni1/public_html/acmed.com/application/controllers/Website.php
Line: 8
Function: __construct
File: /home/zytroni1/public_html/acmed.com/index.php
Line: 318
Function: require_once
Severity: Warning
Message: imagejpeg(./captcha/1777531460.jpg): failed to open stream: Disk quota exceeded
Filename: helpers/captcha_helper.php
Line Number: 609
Backtrace:
File: /home/zytroni1/public_html/acmed.com/application/helpers/common_helper.php
Line: 354
Function: create_captcha
File: /home/zytroni1/public_html/acmed.com/application/controllers/Website.php
Line: 242
Function: generate_captcha
File: /home/zytroni1/public_html/acmed.com/application/controllers/Website.php
Line: 81
Function: productdetail
File: /home/zytroni1/public_html/acmed.com/index.php
Line: 318
Function: require_once
Anaesthesia System KAM-A101 is equipped with color LCD screen for clear display of trends, dosage rate and other setting parameters. Designed to suit adult as well as pediatric patients. System complies with closed, semi-closed, semi-open or assisted ventilation. Integrated sensors and valves ensure risk prevention from system failure and increases patient safety.
| Drive | Electronically controlled, bellow driven |
| Tidal Volume | 0 ml – 1500 ml |
| Gas Configuration | O2, N2O |
| Flow Meter | 1 l/min – 10 l/min |
| LCD Display | 7 inch LCD |
| Vaporizer | Single [Isoflurane / Enflurane / Sevoflurane / Halothane] |
| Fresh Gas Compensation | 25 l/min – 75 l/min |
| I:E Range | 4:1-1:8 |
| Monitoring | VT, MV, BPM, Paw |
| Modes of Ventilation | IPPV, SIMV, SIPPV, Manual |
| Respiration range | 1 bpm – 100 bpm |
| Concentration Range | 0% to 5% |
| Calibration | Automatic |
| Waveforms | Pressure-time, Flow-time, Pressure-volume loop |
| Hypoxic Safety System | N2O cut-off valve / O2 > 25% |
| Alarm | AC power failure, minute volume too high (low), airway pressure too high ( low ) and insufficiency of O2 and N2O |
| Pressure Safety Valve | < 12.5 kPa |
| Volume of CO2 absorber | 1.5 L |
| Power Consumption | 50 VA |
| Power Supply | 100 VAC – 240 VAC, 50 / 60 Hz |
| Battery | [Rechargeable Lead-acid battery] 30 minutes ~ 120 minutes |
| Working Condition | Patient airway pressure range: - 2 kPa ~ 10 kPa Airway monitoring range: 0 ~ 9.9 kPa Pressure limit range: 2.0 kPa ~ 6.0 kPa |
| Dimensions | 1190 x 410 x 710 mm |
| Weight | 82 Kgs |
7 inch color LCD display Pneumatic controlled flow Vaporizer: double (optional) Auto-calibration Suitable for adult as well as pediatric care Comprehensive alarms
Used in Surgical or Gynaecological departments to administer appropriate anaesthesia dosage at a specified rate to ensure effective sedation during surgeries and other invasive diagnostic or interventional procedures.