Anaesthesia System KAM-A102

Anaesthesia System KAM-A102 is equipped with color LCD screen for clear display of trends, dosage rate and other setting parameters. Designed to suit adult as well as pediatric patients. System complies with closed, semi-closed, semi-open or assisted ventilation. Integrated system software allows real-time monitoring for loops, Paw, BPM, VT and lung compliance. Comprehensive audio-visual alarm indication for critical events increases patient safety.

25 Reviews
Drive Electronically controlled, pneumatic driven
Tidal Volume 20 ml – 1500 ml
Gas Configuration O2, N2O
Flow Meter Cascade, 0 L/min -10 L/min
LCD Display 7 inch LCD
Graphic Display Waveforms of P-T, F-T
Vaporizer Isoflurane / Enflurane / Sevoflurane / Halothane
I:E Range 4:1-1:8
Pressure Range 5 mbar - 80 mbar
P trigger Range -20 cmH2O to 20 cmH2O
Respiration range 1 bpm - 99 bpm (1 bpm - 40 bpm under SIMV)
Calibration Automatic
Pipeline Input 280 kPa - 600 kPa
Minute Volume > 18 L/min
PEEP Off
3 - 20 cm H2O
Run-time > 30 minutes up to 2 hours
Hypoxic Safety System N2O cut-off valve / O2 > 25%
Pressure Safety Valve < 12.5 k Pa
Volume of CO2 absorber 1.5 L
Output Pressure 0.4 ± 0.1 mPa
Power Supply AC 220V ± 10%, 50Hz ± 2%
Battery Lead-acid battery 12V, 4Ah
Current 500 mA (Max)
Dimensions 700 x 850 x 1400 mm
Weight 65 Kgs

7 inch color LCD display
Pneumatic controlled flow
Ventilation modes: IPPV, SIMV, Manual, Stand-By
Vaporizer : Double (optional)
Auto-calibration
Suitable for adult as well as pediatric care
ACG outlet (optional)
AG Scavenging system (optional)
Yoke system (optional)
Selectetac (optional)

Used in Surgical or Gynaecological departments to administer appropriate anaesthesia dosage at a specified rate to ensure effective sedation during surgeries and other invasive diagnostic or interventional procedures.

Buy Now: Anaesthesia System KAM-A102

Related To Anaesthesia System

Anaesthesia System KAM-A200

Anaesthesia System KAM-A101

Anaesthesia System KAM-A100
Anaesthesia System KAM-B100

C-Arm X-ray Imaging

Mobile C-Arm X-ray KCX-A100

Mobile C-Arm X-ray KCX-A100

X-Ray Generator : Frequency 40 kHz </br> Power Capacity 3.5 kW

Tube Current : X-ray : 20 mA - 63 mA </br> Fluoroscopy : 8 mA

Tube Voltage : 40 kV ~ 110 kV

Surgical Diathermy

Surgical Diathermy Machine KSD-A100

Surgical Diathermy Machine KSD-A100

Power Consumption : 350 W

Operating Frequency : 330 kHz ─ 460 kHz

Modes : 6 Monopolar modes </br> 2 Bipolar modes

Surgical Diathermy Machine KSD-B100
Surgical Diathermy Machine KSD-B100

Power Consumption : 300 W

Operating Frequency : 416 kHz

Modes : 5 Monopolar modes </br> 2 Bipolar modes